Medication info

Tristell Spory Wipes and Foam

Prescription medicationSolution
Ingredient · strength
Sodium Chlorite 25%›2g / 100gCitric Acid Hydrate›0.75g / 100g
Manufacturer / importer
HP&C Ltd.
Appearance
Part 1 (Foam): A colorless transparent liquid in a plastic container. Part 2 (Wipes): A white non-woven fabric soaked in a citric acid solution contained in a bag.
Packaging
Part 1 (Foam) - 100 milliliters/bottle [1 bottle/box], Part 2 (Wipes) - 1 sheet/bag [50 sheets/box]
Approval status
Active

MFDS item code 201901806 · Approved 2019.03.26

Summary

Main use
Inhibition of microorganisms through disinfection of medical devices (such as endoscopes without channels)
Who uses it
Adults
Adult dosage
To effectively disinfect medical devices, follow the procedures below. A. Before disinfection, clean contaminated medical devices with a detergent and visually confirm that all foreign matter has been removed. B. Disinfect medical devices as follows. 1) Always disinfect your hands before beginning work, and wear sterile gloves while working. 2) Remove one pouch containing a nonwoven fabric sheet (with citric acid) from the product box. 3) Tear open the pouch, then unfold the folded part of the nonwoven fabric sheet flat on your palm. 4) Remove the pump bottle from the product box and take off the cap. If this is the first use after opening, press the pump approximately 2~4 times to activate the foam in the bottle as much as possible. Leave the first foam dispensed from the bottle on the nonwoven fabric sheet, then press the pump 2 more times to apply foam to the sheet. 5) Fold the nonwoven fabric sheet so that the foam does not leak out, and knead it in your hand for 15 seconds to allow it to react. It is ready for use when you smell chlorine. 6) Wipe all surfaces of the medical device at least once with the nonwoven fabric sheet. Then wait 30 seconds. 7) Securely close the cap on the used bottle before storage, and dispose of the nonwoven fabric sheet and gloves in a designated medical waste container. Clean all surfaces of the disinfected medical device using purified water (or cleaning wipes), etc. Use at least 0.5 liters of purified water. This product is used to disinfect reusable medical devices that have no lumen and are heat-sensitive (nasal endoscopes, echocardiography probes, transvaginal ultrasound probes, transesophageal echocardiography probes, transrectal ultrasound probes, laryngoscope blades, intubation endoscopes, pressure-monitoring catheters, and ophthalmic instruments).

Ingredients

Importer
HP&C Ltd.

Efficacy & effects

Inhibition of microorganisms through disinfection of medical devices (such as endoscopes without channels)

View approved original text

Safely disinfects medical instruments such as endoscopes and ultrasound probes to reduce the risk of infection and provides a safe medical environment for patients.

Dosage and Administration

Adult dosage

To effectively disinfect medical devices, follow the procedures below. A. Before disinfection, clean contaminated medical devices with a detergent and visually confirm that all foreign matter has been removed. B. Disinfect medical devices as follows. 1) Always disinfect your hands before beginning work, and wear sterile gloves while working. 2) Remove one pouch containing a nonwoven fabric sheet (with citric acid) from the product box. 3) Tear open the pouch, then unfold the folded part of the nonwoven fabric sheet flat on your palm. 4) Remove the pump bottle from the product box and take off the cap. If this is the first use after opening, press the pump approximately 2~4 times to activate the foam in the bottle as much as possible. Leave the first foam dispensed from the bottle on the nonwoven fabric sheet, then press the pump 2 more times to apply foam to the sheet. 5) Fold the nonwoven fabric sheet so that the foam does not leak out, and knead it in your hand for 15 seconds to allow it to react. It is ready for use when you smell chlorine. 6) Wipe all surfaces of the medical device at least once with the nonwoven fabric sheet. Then wait 30 seconds. 7) Securely close the cap on the used bottle before storage, and dispose of the nonwoven fabric sheet and gloves in a designated medical waste container. Clean all surfaces of the disinfected medical device using purified water (or cleaning wipes), etc. Use at least 0.5 liters of purified water. This product is used to disinfect reusable medical devices that have no lumen and are heat-sensitive (nasal endoscopes, echocardiography probes, transvaginal ultrasound probes, transesophageal echocardiography probes, transrectal ultrasound probes, laryngoscope blades, intubation endoscopes, pressure-monitoring catheters, and ophthalmic instruments).

Precautions

This product should not be used directly on the human body. If it comes into contact with skin, it should be rinsed immediately with plenty of running water, and if the pain persists, a dermatologist should be consulted. If it gets into the eyes, rinse immediately for more than 15 minutes and seek ophthalmological treatment as soon as possible. If this drug is accidentally ingested, give plenty of water or milk and do not induce vomiting, and ensure to seek a doctor's examination. Use this product with caution in a well-ventilated area, preferably in a place with ventilation equipment if necessary. Wear protective equipment such as safety glasses or gloves to protect the eyes and skin and handle it safely. Take care to avoid continuous inhalation of vapor and do not mix with other compounds. Keep out of reach of children, and it is important to store it tightly closed in its original container. Take care to avoid accidental ingestion or consumption, and ensure it is not stored with food. Used product should not be reused and must be disposed of properly.

Side effects

  • Pain
  • Eye impairment
  • Respiratory system impairment

Not everyone experiences these, and they can vary from person to person.

Storage

This product must be stored in a tightly closed container to prevent exposure to air or moisture, and it is important to store it at room temperature between 1 degree and 30 degrees Celsius. Storing it this way will maintain the efficacy of the drug and ensure safe use.

Appearance and packaging

Appearance

Part 1 (Foam): A colorless transparent liquid in a plastic container. Part 2 (Wipes): A white non-woven fabric soaked in a citric acid solution contained in a bag.

Package unit

Part 1 (Foam) - 100 milliliters/bottle [1 bottle/box], Part 2 (Wipes) - 1 sheet/bag [50 sheets/box]

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.

Related searches

Search tags

Suggested searches

This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.