Medication info

Tristel Duo Foam

Prescription medication
Ingredient · strength
Sodium Chlorite 25%›2g / 100gCitric Acid Hydrate›5g / 100g
Manufacturer / importer
HP&C Ltd.
Appearance
Component 1 (Activator): Colorless transparent liquid Component 2 (Base): Light blue transparent liquid
Packaging
Component 1 (Activator) - 125 milliliters/bottle, Component 2 (Base) - 125 milliliters/bottle
Approval status
Active

MFDS item code 202103785 · Approved 2021.05.11

Summary

Main use
Prevention of contamination of ultrasound probes and non-invasive medical devices
Who uses it
Adults
Adult dosage
To effectively disinfect medical devices, follow the procedure below. A. For contaminated medical devices, use a cleaning agent and visually confirm that foreign matter has been removed before proceeding with disinfection. B. Disinfect medical devices using the following procedure. 1) Always disinfect your hands before starting work, and wear medical gloves while working. 2) Prepare a dry nonwoven fabric (dry wipes, etc.). 3) Remove the product's locking cap. If using for the first time after opening, press the pump approximately 2~4 times to activate the foam inside the bottle as much as possible. Leave the first foam dispensed from the bottle on the nonwoven fabric, then press the pump 2 more times to apply the foam to the fabric. 4) Wipe all surfaces of the medical device at least once using the nonwoven fabric. If necessary, use a cotton swab to apply the product to uneven areas. Then wait 30 seconds. 5) Close the cap securely on the used bottle for storage, and dispose of the nonwoven fabric and gloves in a designated medical waste container. After disinfection, the device may be rinsed with purified water (using cleaning wipes), if necessary. This product is heat-sensitive and is used to disinfect reusable medical devices. - Intracavitary ultrasound probes, such as transrectal and transvaginal ultrasound probes - Noninvasive medical devices, such as abdominal ultrasound probes (including those used in invasive procedures), bladder scanners, and blood pressure cuffs

Ingredients

Importer
HP&C Ltd.

Efficacy & effects

Prevention of contamination of ultrasound probes and non-invasive medical devices

View approved original text

Disinfection of ultrasound probes and non-invasive medical devices is extremely important for patient safety. These medical devices are used on multiple patients, so a thorough disinfection process is necessary to prevent infections. Non-invasive devices often come into contact with the skin surface, thus proper disinfection can prevent cross-contamination. In particular, ultrasound probes can be used internally or externally, so the risk of infection can be significantly reduced depending on the disinfection method used. Therefore, it is necessary to use the appropriate disinfectant and follow established disinfection guidelines. This process is crucial for maintaining patient safety and device performance.

Dosage and Administration

Adult dosage

To effectively disinfect medical devices, follow the procedure below. A. For contaminated medical devices, use a cleaning agent and visually confirm that foreign matter has been removed before proceeding with disinfection. B. Disinfect medical devices using the following procedure. 1) Always disinfect your hands before starting work, and wear medical gloves while working. 2) Prepare a dry nonwoven fabric (dry wipes, etc.). 3) Remove the product's locking cap. If using for the first time after opening, press the pump approximately 2~4 times to activate the foam inside the bottle as much as possible. Leave the first foam dispensed from the bottle on the nonwoven fabric, then press the pump 2 more times to apply the foam to the fabric. 4) Wipe all surfaces of the medical device at least once using the nonwoven fabric. If necessary, use a cotton swab to apply the product to uneven areas. Then wait 30 seconds. 5) Close the cap securely on the used bottle for storage, and dispose of the nonwoven fabric and gloves in a designated medical waste container. After disinfection, the device may be rinsed with purified water (using cleaning wipes), if necessary. This product is heat-sensitive and is used to disinfect reusable medical devices. - Intracavitary ultrasound probes, such as transrectal and transvaginal ultrasound probes - Noninvasive medical devices, such as abdominal ultrasound probes (including those used in invasive procedures), bladder scanners, and blood pressure cuffs

Precautions

This product should not be used directly on the human body. If it comes into contact with skin, wash thoroughly with running water immediately, and if pain continues, seek care from a dermatologist. If it gets into the eyes, rinse immediately with clean water for more than 15 minutes, and seek care from an ophthalmologist. Failure to rinse the eyes sufficiently can cause serious damage. If ingested accidentally, drink plenty of water or milk, do not induce vomiting, and seek medical attention immediately. Inducing vomiting can cause respiratory issues. Use in a well-ventilated area, and if necessary, use in a place with ventilation devices. Care should be taken, such as wearing protective goggles or gloves, to protect the eyes and skin. Avoid continuous inhalation of the vapor from this product. Do not mix with other chemicals. Store out of reach of children in a safe place, and keep in the original container tightly closed. Transferring to another container may create risks of misuse or degradation of quality. Special care should be taken to prevent accidental ingestion or swallowing. Ensure it is not stored with food, and do not reuse discarded products.

Storage

This product should be stored in a sealed container to avoid exposure to air and moisture, and it is best stored at room temperature between 1 degrees and 30 degrees Celsius. This helps maintain the effectiveness of the product for a long time.

Appearance and packaging

Appearance

Component 1 (Activator): Colorless transparent liquid Component 2 (Base): Light blue transparent liquid

Package unit

Component 1 (Activator) - 125 milliliters/bottle, Component 2 (Base) - 125 milliliters/bottle

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.