Deterjums Acetic Acid Solution (Acetic Acid 0.2%)
Peracetic Acid Solution 0.2%
OTC medication
EMB Pharmaceutical Co., Ltd.
MFDS item code 202400676 · Notified 2024.03.27
Sterilization and disinfection of medical devices (such as endoscopes and silicone tubes) and inhibition of microbial growth
Used for the sterilization and disinfection of medical devices such as breathing tubes, silicone tubes, vinyl tubes, silicone caps, silicone stoppers, scalpel handles, and endoscopic instruments.
1. Preparation Prepare the disinfectant solution for this medicine as follows. Mix 4 L of Solution 1 with 90 mL of Solution 2. 2. Directions for use A. Fully immerse the pre-cleaned medical instruments in the prepared disinfectant solution. For instruments and equipment with narrow lumens or complex structures, ensure thorough contact with the prepared disinfectant solution by pressure injection or aspiration. If necessary, perform a leak test before use. B. Immerse completely for at least 5 minutes. For sporicidal activity, immerse completely for at least 10 minutes. C. After thorough immersion, remove the instruments and rinse under running sterile purified water for at least 15 seconds. An excess volume of water may be used depending on the intended use. Since disinfectant solution may remain inside instruments with narrow lumens or complex structures, thoroughly rinse them by pressure-injecting sterile purified water or water, or by extending the rinsing time. 3. After disinfection of the medical instruments is complete and before using them, always check for residual disinfectant using a hydrogen peroxide residue test strip or similar method, and confirm that the residual hydrogen peroxide concentration is less than 0.5 ppm.
This drug must not be used on the human body. If it comes into contact with the skin, immediately remove contaminated clothing and wash thoroughly with running water. If pain persists, seek treatment from a dermatologist. If it gets into the eyes, rinse immediately with running water for at least 15 minutes and consult an ophthalmologist. Delaying or insufficient rinsing could cause eye damage. If vapors are inhaled, move to an area with fresh air and consult a specialist. If ingested incorrectly, drink a large amount of water or milk immediately and do not induce vomiting forcibly; seek examination by a specialist. Forcible vomiting may cause respiratory issues. When using and storing, use a container with a lid to prevent vapor from spreading and be cautious with ventilation. If necessary, it is advisable to use it in a well-ventilated area. Wear protective gear such as goggles to avoid contact with eyes, and handle with care. Ensure that the concentration of acetic acid is 0.05% or more for sufficient effect. If organic materials such as blood or bodily fluids remain on the instrument to be disinfected, it may affect the drug's efficacy, so it should be cleaned thoroughly. For complex instruments like endoscopes, follow the cleaning method recommended by the manufacturer. After cleaning, ensure that there is no moisture left on the instrument before immersing it in the disinfectant. Check for residual acetic acid, and if there is any, increase the rinsing time to eliminate it. To kill spores, immerse for more than 10 minutes, and avoid continuous use for over an hour depending on the instrument. Components made of natural rubber or latex may deteriorate upon repeated use, reducing disinfectant effectiveness. Instruments that are cracked or rusted should not be used as they may decrease disinfection effectiveness. During disinfection tasks, wear protective equipment such as rubber gloves, gowns, masks, and goggles to prevent contact with infection and solutions. The prepared disinfectant should be stored in a sealed container, and the lid should be closed during use. Avoid direct sunlight and store at room temperature; it can be used until the acetic acid concentration is below 0.05%. It is acidic, so mixing with chlorine-based preparations can produce dangerous chlorine gas, so mixing should be strictly avoided. When disposing of it, flush with a large amount of water, and if necessary, neutralize it using an alkali or reducing agent before disposal. Store out of reach of children, and keep it in its original container with the lid tightly closed.
Not everyone experiences these, and they can vary from person to person.
This drug should be stored in a tightly closed container to prevent air or moisture from entering, and should be kept at room temperature between 1 degree and 30 degrees. Storing it this way helps maintain the drug's efficacy for a longer period.
Preparation 1: A colorless and transparent liquid with the smell of acetic acid. Preparation 2: A colorless to pale yellowish transparent liquid.
Preparation 1 - 4 liters/bottle, Preparation 2 - 90 milliliters/bottle
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Peracetic Acid Solution 0.2%
OTC medication
EMB Pharmaceutical Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
Person Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
Valley Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
Samhyun Pharmaceutical Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.