Pherastel One Shot Liquid (Guaacetate Solution)
Peracetic Acid Solution
OTC medication
HP&C Co., Ltd.
MFDS item code 202204543 · Notified 2022.12.20
Prevention of infection through chemical sterilization and disinfection of medical devices
To safely use medical devices, chemical methods must be performed for sterilization and disinfection. This process is crucial for eliminating or killing bacteria, viruses, fungi, etc. that may exist on the instruments, thus preventing infections. Chemical sterilizers use various chemical substances to effectively remove microorganisms and can be applied to medical instruments where high-temperature sterilization is difficult. The disinfection process is slightly less effective than sterilization, but it is sufficiently useful to reduce the risk of infection. This method is used in medical settings to ensure patient safety and improve infection control.
1. Preparation Prepare the disinfectant solution for this product as follows. Mix the product (80mL) with water (7,920mL), or the product (110 mL) with water (7,890 mL), and use. 2. Directions for use 1) First, completely immerse medical devices that have been washed with water in the prepared disinfectant solution. For devices and equipment with small openings or complex structures, use pressure injection or suction to ensure they are thoroughly wetted with the prepared solution. 2) Completely immerse for at least 10 minutes if the prepared disinfectant solution has a concentration of 1500 ppm or higher, or for at least 5 minutes if it has a concentration of 2000 ppm or higher (chemical sterilization). 3) After sufficient immersion, remove the devices and rinse them with running purified water for at least 15 seconds to ensure that no residue of this product remains. Water may also be used depending on the intended purpose. Disinfectant solution can easily remain inside devices with small openings or complex structures; therefore, rinse thoroughly by injecting purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical devices is complete, confirm that no residue of this product or its decomposition product (hydrogen peroxide) remains before using the devices.
This medicine must not be used directly on the human body. If it comes into contact with the skin, remove contaminated clothing immediately and wash thoroughly with running water; if pain persists, consult a dermatologist. In case of contact with the eyes, rinse immediately with running water for at least 15 minutes and consult an ophthalmologist; delayed or insufficient washing can cause eye damage. If vapor is inhaled, move to an area with fresh air immediately and consult a specialist. If ingested accidentally, drink a large amount of water or milk and do not induce vomiting; consult a specialist without delay. Forcing vomiting may cause respiratory problems. Store this product in a container with a lid to prevent vapor dispersion, and it is advisable to use it in a well-ventilated area. To protect eyes and skin, wear protective gear such as goggles, gloves, and masks, and take care not to inhale the powder of the product. Before disinfection, clean up any contaminants thoroughly, and be careful with storage and handling to avoid accidental ingestion. Keep out of reach of children, and do not transfer the product from its original container to another. Always store it tightly closed in its original container to maintain the quality of the product.
Not everyone experiences these, and they can vary from person to person.
This medicine should be stored in a sealed container to prevent exposure to air or moisture, and it is best kept at room temperature between 1 degree and 30 degrees Celsius. Storing it this way will help maintain the effectiveness of the medicine for a longer period.
A colorless and transparent liquid with a peculiar irritating odor contained in a plastic container.
250 milliliters/bottle, 500 milliliters/bottle, 750 milliliters/bottle, 875 milliliters/bottle, 5 liters/bottle, 6 liters/bottle
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Peracetic Acid Solution
OTC medication
HP&C Co., Ltd.
Peracetic Acid Solution 100g
Prescription medication
Person Co., Ltd.
Peracetic Acid Solution
Prescription medication
Huons Meditech Co., Ltd.
Peracetic Acid Solution
OTC medication
Joyang Medical Industry Co., Ltd.
Peracetic Acid Solution
OTC medication
Person Co., Ltd.
Peracetic Acid Solution
OTC medication
Wizpharm Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.