Medication info

Wikryn P.A. Liquid (High Concentration Acetic Acid Balanced Mixture)

OTC medication
Ingredient · strength
Highly Concentrated Balanced Mixture of Acetic Acid›Strength being verified
Manufacturer / importer
WGP Pharmaceutical Co., Ltd.
Appearance
Part 1: A colorless, transparent liquid with a smell of acetic acid in a blue plastic container Part 2: A colorless to light yellow transparent liquid with a distinctive aroma in a blue plastic container
Packaging
Part 1: 5L/bottle Part 2: 5L/bottle
Approval status
Active

MFDS item code 202200290 · Notified 2022.01.18

Summary

Main use
Inhibition of microorganisms through sterilization and disinfection of medical devices (including endoscopes)
Who uses it
Adults
Adult dosage
1. Preparation Prepare the disinfectant solution for this drug as follows. Mix 1 component (100 mL), 2 component (100 mL), and water (7800 mL) in the specified proportions before use. 2. Method of use 1) First, completely immerse medical instruments that have been washed with water in the prepared disinfectant solution. For instruments and equipment with fine lumens or complex structures, use pressure injection or suction to ensure they are thoroughly wetted with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. 3) After thorough immersion, remove the instruments and rinse them for at least 15 seconds with flowing sterile purified water to ensure no residue of this drug remains. Water may also be used depending on the intended use. Since disinfectant solution can easily remain inside instruments with fine lumens or complex structures, rinse thoroughly by pressure-injecting sterile purified water or water, or by extending the rinsing time. 3. After disinfecting medical instruments, confirm that no residues of this drug or its decomposition product (hydrogen peroxide) remain before using the instruments.

Ingredients

Manufacturer
WGP Pharmaceutical Co., Ltd.

Efficacy & effects

Inhibition of microorganisms through sterilization and disinfection of medical devices (including endoscopes)

View approved original text

This product is used for the sterilization and disinfection of medical devices, including heat-sensitive endoscopes.

Dosage and Administration

Adult dosage

1. Preparation Prepare the disinfectant solution for this drug as follows. Mix 1 component (100 mL), 2 component (100 mL), and water (7800 mL) in the specified proportions before use. 2. Method of use 1) First, completely immerse medical instruments that have been washed with water in the prepared disinfectant solution. For instruments and equipment with fine lumens or complex structures, use pressure injection or suction to ensure they are thoroughly wetted with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. 3) After thorough immersion, remove the instruments and rinse them for at least 15 seconds with flowing sterile purified water to ensure no residue of this drug remains. Water may also be used depending on the intended use. Since disinfectant solution can easily remain inside instruments with fine lumens or complex structures, rinse thoroughly by pressure-injecting sterile purified water or water, or by extending the rinsing time. 3. After disinfecting medical instruments, confirm that no residues of this drug or its decomposition product (hydrogen peroxide) remain before using the instruments.

Precautions

This medicine should not be used directly on the body. If it comes into contact with skin, immediately remove contaminated clothing and wash thoroughly with running water; if pain persists, seek treatment from a dermatologist. If it gets into the eyes, immediately wash with running water for more than 15 minutes and seek treatment from an ophthalmologist, as delayed or insufficient washing can cause eye damage. If vapors are inhaled, move to an area with fresh air and consult a specialist. In case of accidental ingestion, drink a large amount of water or milk and suppress vomiting; immediate examination by a specialist is necessary. This product has a strong irritating smell, so it should be stored and used in a well-ventilated area, and dispensed in dedicated equipment or well-ventilated places to avoid inhaling vapors. Wear protective glasses to prevent contact with eyes and prepare washing facilities before handling. When handling, wear protective glasses and a mask to protect eyes and respiratory organs, and always ensure proper ventilation. Before use, check that the peracetic acid concentration is 0.2% or higher, and clean any contaminants such as blood or bodily fluids thoroughly from instruments before disinfection. After cleaning, completely remove moisture from the instruments before immersing them in the disinfectant, and after disinfection, check for residues to rinse appropriately. To kill spores, immersion must last at least 5 minutes, and instruments should not be used continuously for over 1 hour as it could cause rust or deterioration. Instruments made of natural rubber or untreated rubber may undergo changes after repeated use, and should not be used on cracked or rusty instruments. During disinfection, wear protective equipment such as rubber gloves, gowns, masks, and goggles to prevent infection and chemical contact. When storing, be careful to avoid accidental ingestion, and do not inhale the disinfectant while preparing it. Prepared disinfectant should be stored in a container with a lid, away from direct sunlight and at room temperature. This product is acidic, so do not mix it with chlorine-based preparations as it will generate harmful chlorine gas. Absolutely do not mix. When disposing, dilute with a large amount of water or mix with an alkali to neutralize, and use a reducing agent for decomposition before handling according to relevant regulations. In preclinical studies, the components of this product showed slight carcinogenicity on the skin, and there have also been reports of lung tumors occurring upon inhalation, so extreme caution must be exercised during handling.

Side effects

Pain, visual impairment, respiratory system disorder, irritation of mucous membranes such as eyes and respiratory tract

Not everyone experiences these, and they can vary from person to person.

Storage

This medication should be stored in a tightly sealed container to avoid exposure to air and moisture, preferably at temperatures between 1 degrees and 30 degrees Celsius. Storing it this way can help maintain the effectiveness of the medication for a long time.

Appearance and packaging

Appearance

Part 1: A colorless, transparent liquid with a smell of acetic acid in a blue plastic container Part 2: A colorless to light yellow transparent liquid with a distinctive aroma in a blue plastic container

Package unit

Part 1: 5L/bottle Part 2: 5L/bottle

Same-ingredient medicines

Even with the same ingredient, strength, dosage form and how it is taken can differ.

Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.

Related searches

Search tags

Suggested searches

This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.