SAFE OPHIAEAC (Orthophthalaldehyde)

Prescription medicationSolution
Ingredient · strength
o-Phthalaldehyde›0.55g / 100mL
Manufacturer / importer
Valley Co., Ltd.
Appearance
Colorless liquid
Packaging
4 liters/bottle
Approval status
Active

MFDS item code 202001231 · Approved 2020.02.20

Summary

Main use
Suppression of microorganisms through disinfection and sterilization of medical devices (e.g., endoscopes)
Who uses it
Adults
Adult dosage
1. Preparation Use undiluted. 2. Indications Disinfection of instruments highly contaminated with microorganisms or organic matter, instruments directly applied to subcutaneous tissue or mucous membranes, or instruments suspected of being contaminated with hepatitis B virus. 3. Instruments Endoscopes, instruments with lenses, anesthesia equipment, ventilators, hemodialysis equipment, obstetric and urological instruments, dental instruments or their accessories, thermometers, and rubber or plastic instruments that cannot be heat sterilized, etc. 4. Directions for use 1) Completely immerse the items to be disinfected in the solution. Take care to ensure that instruments with cavities are thoroughly contacted by the solution. 2) Usually, immerse instruments for at least 5 minutes for disinfection. 3) After immersion, remove the instruments and remove any adhering material, then rinse thoroughly with a large amount of sterile water. Water may also be used depending on the intended use. For instruments with cavities, take care to rinse the inner passages.

Ingredients

Manufacturer
Valley Co., Ltd.

Efficacy & effects

Suppression of microorganisms through disinfection and sterilization of medical devices (e.g., endoscopes)

View approved original text

The sterilization and disinfection of medical instruments such as endoscopes are very important for patient safety. This process is used to effectively remove microorganisms such as bacteria, viruses, and fungi that may be present on the instruments, reducing the risk of infection. By maintaining the cleanliness of medical devices through appropriate disinfection procedures, it prevents cross-contamination and protects the health of patients. Therefore, the sterilization and disinfection of medical instruments like endoscopes are essential processes for creating a safe medical environment.

Dosage and Administration

Adult dosage

1. Preparation Use undiluted. 2. Indications Disinfection of instruments highly contaminated with microorganisms or organic matter, instruments directly applied to subcutaneous tissue or mucous membranes, or instruments suspected of being contaminated with hepatitis B virus. 3. Instruments Endoscopes, instruments with lenses, anesthesia equipment, ventilators, hemodialysis equipment, obstetric and urological instruments, dental instruments or their accessories, thermometers, and rubber or plastic instruments that cannot be heat sterilized, etc. 4. Directions for use 1) Completely immerse the items to be disinfected in the solution. Take care to ensure that instruments with cavities are thoroughly contacted by the solution. 2) Usually, immerse instruments for at least 5 minutes for disinfection. 3) After immersion, remove the instruments and remove any adhering material, then rinse thoroughly with a large amount of sterile water. Water may also be used depending on the intended use. For instruments with cavities, take care to rinse the inner passages.

Precautions

This drug can rarely cause allergic reactions, so caution is needed. In particular, the risk of allergic reactions increases when healthcare workers use it in poorly ventilated spaces or do not wear personal protective equipment properly. Care should be taken to avoid direct contact with eyes, skin, or clothing. Contact with the eyes can cause irritation, and contact with the skin can lead to temporary discoloration. Repeated contact with the skin can cause hypersensitivity, so caution is advised. If it comes into contact with the eyes, rinse immediately with plenty of water for more than 15 minutes and seek medical attention. If it comes into contact with the skin, it should also be washed off immediately, and this drug should not be made into a spray or aerosol form. Care should be taken to avoid contamination with food, and if ingested, do not induce vomiting but drink plenty of water and seek medical help immediately. Contact with the mouth can damage mucous membranes, making gastric lavage difficult. Exposure to this drug's vapor can irritate the respiratory system and eyes, so care should be taken not to inhale the vapor. Inhalation of the vapor can cause a stinging sensation in the nose and throat, coughing, chest pain, and may worsen symptoms of asthma or bronchitis. If such symptoms occur, inhale fresh air, obtain oxygen if breathing becomes difficult, and seek medical attention if symptoms persist. This drug should only be used on specific medical instruments, and the cleaning and disinfection procedures recommended by the manufacturer of the device must be strictly followed. Especially when used for transesophageal echocardiography (TEE), the recommendations provided in the instruction manual must be adhered to rigorously. Otherwise, chemical burns or hypersensitivity reactions and discoloration may occur in the mouth, throat, esophagus, and stomach. This drug should not be used on patients with hypersensitivity to its components and should not be used to disinfect urological instruments in patients with a history of bladder cancer. Additionally, it is not suitable for the sterilization of heat-sensitive medical instruments, so biological monitoring procedures should be followed when sterilization is necessary. Medical devices used on sterilized areas of the human body, such as cataract surgery instruments, must not use this drug, and it should always be used in well-ventilated areas. Reusable instruments must be thoroughly cleaned before disinfection, as any residual dirt or lubricant will reduce the effectiveness of disinfection. When disinfecting, appropriate gloves, eye protection, and waterproof surgical gowns should be worn, and when using latex gloves, it is recommended to double up or change them frequently. Users must follow the instructions for use, and manufacturers of reusable devices must provide validated application procedures when using this drug. When using an automatic endoscope cleaning device, the validated procedures must be followed, and the contact conditions are 25°C for 5 minutes. Finally, it is important to measure the concentration of this drug before use with dedicated test strips.

Side effects

Allergic reactions, eye irritation, temporary skin discoloration, skin hypersensitivity, irritation and chemical burns of the oral cavity, pharynx, esophagus, tingling sensation in the nose and throat, secretions, cough, chest pain, exacerbation of asthma and bronchitis

Not everyone experiences these, and they can vary from person to person.

Storage

This drug should be stored in a tightly sealed container to protect it from air and moisture. The storage temperature should ideally be maintained between 15°C and 30°C at room temperature.

Appearance and packaging

Appearance

Colorless liquid

Package unit

4 liters/bottle

Same-ingredient medicines

Even with the same ingredient, strength, dosage form and how it is taken can differ.

Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.

Related searches

Search tags

Suggested searches

This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.