Summary
- Main use
- Prevention of infection through chemical sterilization and disinfection of medical devices
- Who uses it
- Adults
- Adult dosage
- 1. Preparation Prepare the disinfectant solution for this product as follows. Mix Part 1 (4000 mL) and Part 2 (270mL) before use. 2. Method of use 1) Thoroughly immerse medical instruments, prewashed with water, in the prepared disinfectant solution. For instruments with narrow channels or complex structures, and for machinery, use pressure injection or suction to ensure thorough contact with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. To inactivate spores, immerse completely for at least 10 minutes. 3) After thorough immersion, remove the instruments and rinse for at least 15 seconds under running sterile purified water. Water may also be used depending on the intended use. Since disinfectant solution may remain inside instruments with narrow channels or complex structures, thoroughly rinse them by pressure injection of sterile purified water or water, or by extending the rinsing time. 3. After disinfection of medical instruments is complete and before using the instruments, be sure to check for residual amounts of this medicine using a hydrogen peroxide residue test strip or similar, and confirm that the concentration is less than 0.5 ppm as hydrogen peroxide.
Ingredients
- Manufacturer
- Person Co., Ltd.
Efficacy & effects
Prevention of infection through chemical sterilization and disinfection of medical devices
View approved original textHide original text
Chemical sterilization and disinfection are performed to use medical devices safely. This process effectively removes bacteria, viruses, and other microorganisms present on the medical devices to reduce the risk of infection. Sterilization signifies complete microbial removal, while disinfection reduces the number of microorganisms to a safe level. It is an essential procedure to maintain a safe usage environment for instruments used primarily in medical settings. These methods significantly help protect the health of both patients and healthcare personnel. Therefore, chemical sterilization and disinfection of medical devices are effectively used for infection prevention.
Dosage and Administration
Adult dosage
1. Preparation Prepare the disinfectant solution for this product as follows. Mix Part 1 (4000 mL) and Part 2 (270mL) before use. 2. Method of use 1) Thoroughly immerse medical instruments, prewashed with water, in the prepared disinfectant solution. For instruments with narrow channels or complex structures, and for machinery, use pressure injection or suction to ensure thorough contact with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. To inactivate spores, immerse completely for at least 10 minutes. 3) After thorough immersion, remove the instruments and rinse for at least 15 seconds under running sterile purified water. Water may also be used depending on the intended use. Since disinfectant solution may remain inside instruments with narrow channels or complex structures, thoroughly rinse them by pressure injection of sterile purified water or water, or by extending the rinsing time. 3. After disinfection of medical instruments is complete and before using the instruments, be sure to check for residual amounts of this medicine using a hydrogen peroxide residue test strip or similar, and confirm that the concentration is less than 0.5 ppm as hydrogen peroxide.
Precautions
This product should not be used directly on the human body. If it comes into contact with skin, immediately remove any contaminated clothing and wash thoroughly with clean water; if pain persists, consult a dermatologist. In the event of contact with eyes, rinse immediately for more than 15 minutes with running water and consult an ophthalmologist, as delayed washing can cause eye damage. If inhaled, move to an area with fresh air and consult a specialist. In case of accidental ingestion, drink a large amount of water or milk and do not induce vomiting; seek medical examination immediately. Due to its pungent odor, it should be stored and used in a well-ventilated area, and facilities to avoid steam inhalation should be used. Wear protective eyewear to prevent eye contact, and ensure facilities and water for washing are prepared upon use. Steam can irritate eyes and the respiratory system, so wear protective gear and avoid inhalation or contact, and ensure good ventilation while using the product. Before use, verify that the concentration of peracetic acid is sufficiently high, and any contaminants such as blood or bodily fluids remaining on instruments may reduce disinfection efficacy, so wash them thoroughly. Completely remove moisture from instruments before disinfection, and after disinfection, check for the presence of peracetic acid residue to ensure no remnants remain. To kill spores, the instruments should be immersed for more than 10 minutes, and for certain instruments, it is advisable not to use them for more than one hour. Instruments made of natural rubber or latex may be damaged due to repeated use, so verify before use. It is advisable not to use this product on instruments that are scratched or rusty. During disinfection, wear protective equipment such as rubber gloves, gowns, masks, and goggles to prevent contact with infectious materials and liquid. When storing, ensure that children or others do not accidentally ingest the product, and do not inhale it through the mouth. The prepared disinfection solution should be stored in a container with a lid, avoiding direct sunlight and keeping it at room temperature. This product is acidic, so do not mix with chlorine-containing agents, as harmful chlorine gas may form. When disposing of the product, dilute or neutralize it with a large amount of water and wear protective gear to avoid contact with the solution during the disposal process. There have been reports in non-clinical studies indicating that the ingredients of this product may exhibit weak carcinogenicity and induce lung tumors, so caution is required during use.
Side effects
- Pain
- eye impairment
- mucous membrane irritation
Not everyone experiences these, and they can vary from person to person.
Storage
This product may be sensitive to air and moisture, so it should be stored in a tightly sealed container. The storage temperature should be maintained at room temperature between 1 degree and 30 degrees.
Appearance and packaging
Appearance
Component 1: Colorless transparent liquid with a vinegar (acetic acid) smell in a plastic container Component 2: Colorless transparent liquid in a plastic container
Package unit
Component 1: 4L/bottle Component 2: 270mL/bottle
Questions about this medicine
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.