Summary
- Main use
- Suppression of microorganisms by sterilizing and disinfecting medical devices (such as endoscopes)
- Who uses it
- Adults
- Adult dosage
- 1. Preparation of the solution Prepare the disinfectant solution for this product as follows. Mix 1 part (100 mL) of Solution 1, 1 part (100 mL) of Solution 2, and 78 parts (7800 mL) of water before use. 2. Directions for use 1) First, completely wet the medical devices that have been washed with water in the prepared disinfectant solution. For devices and instruments with fine openings or complex structures, use pressure injection or suction to ensure they are thoroughly wetted with the prepared solution. 2) Immerse completely for at least 5 minutes. 3) After thorough immersion, remove the devices and rinse them with a continuous flow of sterile purified water for at least 15 seconds to ensure no residue of this product remains. Water may also be used depending on the intended use. Since disinfectant solution can easily remain inside devices with fine openings or complex structures, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical devices is complete, confirm that no residue of this product or its decomposition product (hydrogen peroxide) remains before using the devices.
Ingredients
- Manufacturer
- Huons Meditec Co., Ltd.
Efficacy & effects
Suppression of microorganisms by sterilizing and disinfecting medical devices (such as endoscopes)
View approved original textHide original text
This medical solution is used for sterilization and disinfection of various medical instruments including heat-sensitive endoscopes. This helps to reduce the risk of infection and maintain a safe medical environment.
Dosage and Administration
Adult dosage
1. Preparation of the solution Prepare the disinfectant solution for this product as follows. Mix 1 part (100 mL) of Solution 1, 1 part (100 mL) of Solution 2, and 78 parts (7800 mL) of water before use. 2. Directions for use 1) First, completely wet the medical devices that have been washed with water in the prepared disinfectant solution. For devices and instruments with fine openings or complex structures, use pressure injection or suction to ensure they are thoroughly wetted with the prepared solution. 2) Immerse completely for at least 5 minutes. 3) After thorough immersion, remove the devices and rinse them with a continuous flow of sterile purified water for at least 15 seconds to ensure no residue of this product remains. Water may also be used depending on the intended use. Since disinfectant solution can easily remain inside devices with fine openings or complex structures, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical devices is complete, confirm that no residue of this product or its decomposition product (hydrogen peroxide) remains before using the devices.
Precautions
This product must not be used directly on the human body. If it comes into contact with skin, remove contaminated clothing immediately and wash thoroughly with running water, and consult a dermatologist if pain persists. If it gets into the eyes, rinse immediately with running water for at least 15 minutes, and consult an ophthalmologist; delayed or insufficient rinsing may cause damage to the eyes. In the case of inhalation of vapors, move to an area with fresh air and consult a specialist. If swallowed accidentally, drink a large amount of water or milk immediately, do not induce vomiting, and seek medical attention. This product has a strong irritating odor, so it should be stored and used in a well-ventilated area, and prepared using dedicated equipment or in facilities with good ventilation to avoid inhalation of vapors. Protective eyewear should be worn to prevent contact with the eyes, and preparation should be done in a location equipped with a washing facility. Vapor can irritate respiratory pathways and eye mucosa, so wear protective eyewear and a mask, and be cautious about ventilation. Before use, confirm that the concentration of peracetic acid is above 0.2%, and thoroughly clean any blood or organic matter remaining on the instruments to enhance disinfection efficacy. After cleaning, ensure all moisture is completely removed and soak in the disinfectant, checking for any residues to ensure no residue remains. For spore destruction, instruments should be submerged for more than 5 minutes and should not be used continuously for more than 1 hour. Medical devices made of natural rubber or raw rubber may undergo degradation, so caution should be taken, and they should not be used on cracked or rusty instruments. During disinfection, protective equipment such as rubber gloves, gowns, masks, and protective goggles must be worn to prevent contact with infections and disinfectants. Care should be taken in storage and handling to prevent accidental ingestion or swallowing, and aspirating during preparation should be avoided. The prepared disinfectant should be stored in a capped container, protected from direct sunlight, and kept at room temperature. The supersaturated Component 2 may precipitate crystals, so it should be dissolved in warm water before use and should not be stored below 0 degrees Celsius. Disinfectants should only be used when the concentration of peracetic acid is above 0.2%, and confirmation is needed as the concentration may decrease in the presence of moisture or organic matter. Being acidic, it should never be mixed with chlorine-based agents as this could produce toxic chlorine gas. Instruments made of polyvinyl chloride or silicone resin may discolor, so caution should be exercised. When disposing of this product, it should be diluted with a large amount of water or neutralized with an alkali, and disposed of safely according to relevant regulations. Non-clinical studies have reported that the components of this product may have weak carcinogenicity and may induce lung tumors, so extra caution is warranted during handling.
Side effects
Pain, visual disturbances, respiratory disturbances, irritation of mucous membranes such as eyes and respiratory tract
Not everyone experiences these, and they can vary from person to person.
Storage
This product should be kept in a sealed container to protect it from air and moisture and is best stored at room temperature between 1 and 30 degrees Celsius. Maintaining an appropriate temperature will help preserve the efficacy of the product.
Appearance and packaging
Appearance
Component 1: A colorless transparent liquid with an acetic acid odor contained in a white plastic container. Component 2: A colorless to pale yellow transparent liquid with a distinctive smell contained in a white plastic container.
Package unit
Component 1: 5L/bottle Component 2: 5L/bottle