Summary
- Main use
- Suppression of microorganisms through sterilization and disinfection of medical devices
- Who uses it
- Adults
- Adult dosage
- 1. Preparation Prepare the disinfectant solution for this product as follows. Mix 4 L of Solution 1 with 180 mL of Solution 2. 2. Directions for use 1) Thoroughly wet pre-cleaned medical devices with the prepared disinfectant solution. For devices with narrow lumens or complex structures, and for machinery, use pressure injection or suction to ensure they are thoroughly wetted with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. To kill spores and Mycobacterium tuberculosis, immerse completely for at least 10 minutes. 3) After immersion, remove the devices and rinse with running sterile purified water for at least 15 seconds to ensure no residue of this product remains. A larger volume of water may be used depending on the intended use. Disinfectant solution can remain inside devices with narrow lumens or complex structures; therefore, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical devices is complete, confirm that no residue of this product or its decomposition product (hydrogen peroxide) remains before using the devices.
Ingredients
- Manufacturer
- (Co., Ltd.) Huons Meditech
Efficacy & effects
Suppression of microorganisms through sterilization and disinfection of medical devices
View approved original textHide original text
Sterilization and disinfection are critical to prevent infection when using medical devices. Sterilization means completely eliminating all microorganisms and is primarily used for surgical instruments and syringes. Disinfection reduces the number of pathogenic microorganisms and is mainly used to keep the skin or surfaces of medical instruments clean. These two methods are essential to reduce the risk of infection in medical settings and ensure patient safety. Therefore, the sterilization and disinfection of medical devices are important procedures that help in the prevention of infection and the success of treatment processes.
Dosage and Administration
Adult dosage
1. Preparation Prepare the disinfectant solution for this product as follows. Mix 4 L of Solution 1 with 180 mL of Solution 2. 2. Directions for use 1) Thoroughly wet pre-cleaned medical devices with the prepared disinfectant solution. For devices with narrow lumens or complex structures, and for machinery, use pressure injection or suction to ensure they are thoroughly wetted with the prepared disinfectant solution. 2) Immerse completely for at least 5 minutes. To kill spores and Mycobacterium tuberculosis, immerse completely for at least 10 minutes. 3) After immersion, remove the devices and rinse with running sterile purified water for at least 15 seconds to ensure no residue of this product remains. A larger volume of water may be used depending on the intended use. Disinfectant solution can remain inside devices with narrow lumens or complex structures; therefore, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical devices is complete, confirm that no residue of this product or its decomposition product (hydrogen peroxide) remains before using the devices.
Precautions
This medication should not be used directly on humans. If it comes into contact with the skin, immediately remove contaminated clothing and wash thoroughly with running water; if pain persists, consult a dermatologist. If it enters the eyes, it should be rinsed immediately with running water for more than 15 minutes and seek treatment from an ophthalmologist; delayed or insufficient rinsing may cause eye damage. If inhaled, it is important to move to an area with fresh air and consult a specialist. If accidentally swallowed, drink a large amount of water or milk but do not induce vomiting; be sure to seek medical attention. Forcing vomiting can cause respiratory problems. When using this medication, store it in a container with a lid to prevent vapor release and use it in a well-ventilated area. Additionally, be cautious and wear protective goggles to avoid contact with the eyes. Before use, check that the glycolic acid concentration is over 0.05%, and ensure that any devices to be disinfected are cleaned of contaminants such as blood or body fluids first. After cleaning, remove moisture thoroughly and submerge in the disinfectant for effectiveness. After disinfection, check for residues; if residuals are present, extend the rinsing time to remove them completely. To kill spores, they should be soaked for more than 10 minutes, and avoid continuous use for over 1 hour as it may damage the devices. Check rubber or latex instruments, as they may deform or lose sterilizing effectiveness upon repeated use, and avoid using any instruments that are cracked or rusty. During disinfection procedures, always wear protective equipment such as rubber gloves, gowns, masks, and goggles to prevent infection and exposure to chemicals. Store out of reach of children, replace in the original container, tightly close the lid, avoid direct sunlight, and keep at room temperature. This product is acidic and should never be mixed with other chlorine-based preparations as it may produce hazardous gases. When disposing, dilute with a large amount of water or use an alkali or reducing agent for neutralization, and safely handle according to relevant regulations.
Side effects
- Pain
- visual impairment
- respiratory system disorders
Not everyone experiences these, and they can vary from person to person.
Storage
This medication is sensitive to air and moisture, so it must be stored in a tightly sealed container. It is important to maintain a storage temperature between 1 degrees and 30 degrees Celsius at room temperature. This way, the medication's effectiveness and safety can be preserved over time.
Appearance and packaging
Appearance
Component 1: A colorless and transparent liquid with a vinegar smell in a white plastic container Component 2 [Apple Scent]: A colorless to pale yellow transparent liquid with a distinctive scent in a polyethylene pouch Component 2 [Unscented]: Polyethylene pouch
Package unit
Component 1: 4L/bottle Component 2: 180mL/pack
Questions about this medicine
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.