Peracetic Acid Solution (0.2% Acetic Acid)
Peracetic Acid Solution 0.2%
OTC medication
Valley Co., Ltd.
MFDS item code 201708524 · Notified 2017.12.22
Suppression of microorganisms through sterilization and disinfection of medical devices (endoscopes, silicone tubes, etc.)
Used for sterilization and disinfection to safely use medical instruments such as tubes, silicone caps, silicone stoppers, handle of scalpel, and endoscopes.
1. Preparation Prepare the disinfectant solution for this drug as follows. Mix 4 L of Solution 1 with 90 mL of Solution 2. 2. Instructions for use A. Completely immerse pre-cleaned medical instruments in the prepared disinfectant solution. For instruments and equipment with narrow lumens or complex structures, ensure they are sufficiently wetted with the prepared disinfectant solution by pressurized injection or aspiration. If necessary, perform a leak test before use. B. Immerse completely for at least 5 minutes. To achieve spore inactivation, immerse completely for at least 10 minutes. C. After sufficient immersion, remove the instruments and rinse them under running sterile purified water for at least 15 seconds. An excess amount of water may be used depending on the intended use. Since disinfectant solution may remain inside instruments with narrow lumens or complex structures, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time. 3. After disinfection of the medical instruments is complete, before using them, be sure to check for residues of this drug using a hydrogen peroxide residue test strip or similar test, and confirm that the hydrogen peroxide concentration is less than 0.5 ppm.
This product should not be used directly on the human body. If it comes into contact with skin, remove contaminated clothing and wash thoroughly with running water. If pain persists, seek consultation from a dermatologist. If it enters the eyes, rinse immediately with running water for at least 15 minutes and seek care from an ophthalmologist. If inhaled, move to an area with fresh air and consult a professional. If accidentally ingested, drink a large amount of water or milk, do not induce vomiting, and ensure to seek medical attention. When using, store it in a tightly closed container to prevent vapor from escaping and ensure good ventilation. Wear protective eyewear to avoid contact with eyes, and if contact occurs, wash immediately with water and seek professional treatment. Use only if the concentration of peracetic acid is sufficiently high, therefore check the concentration before use. Before disinfection, completely remove any contaminants such as blood or bodily fluids from the instruments, and follow the manufacturer’s cleaning instructions for complex instruments. After cleaning, ensure that the instruments are thoroughly dried before submerging them in the disinfectant. After disinfection, check for residual peracetic acid, and if any residue remains, remove it through appropriate rinsing methods. For spore sterilization purposes, submerge for more than 10 minutes, and avoid continuous use for more than 1 hour. Instruments made of natural rubber or latex may be damaged upon repeated use; hence, inspection is necessary. Instruments that are cracked or rusty should not be used. During disinfection tasks, protective equipment such as rubber gloves, gowns, masks, and protective glasses must be worn at all times. During storage, keep out of reach of children, and store in the original container with the lid tightly closed. When preparing the disinfectant, use a container with a lid and keep it closed during use. Prepared disinfectants should be stored at room temperature away from direct sunlight, and should be used only until the concentration of 0.05% is reached. Being an acid component, do not mix it with chlorine-based agents, as harmful chlorine gas may be produced. When disposing, flush down with large amounts of water, and ensure proper treatment through neutralization processes. During disposal, wear protective equipment such as gloves, protective goggles, and masks to avoid direct contact with the medication.
Not everyone experiences these, and they can vary from person to person.
Do not use this product in conjunction with chlorine-based agents such as hypochlorites.
This product must be stored in a tightly sealed container to prevent exposure to air or moisture. The storage temperature should be maintained at room temperature between 1 to 30 degrees. This way, the effectiveness of the product can be well preserved, ensuring safe usage.
1.1 Prescription 1 Component 1: Colorless, transparent liquid with the smell of acetic acid Component 2: Colorless, transparent liquid with the smell of alcohol 1.2 Prescription 2 Component 1: Colorless, transparent liquid with the smell of acetic acid
(Component 1) 4 L/plastic bottle, (Component 2) 90 mL/plastic bottle
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Peracetic Acid Solution 0.2%
OTC medication
Valley Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
Person Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
EMB Pharmaceutical Co., Ltd.
Peracetic Acid Solution 0.2%
OTC medication
Samhyun Pharmaceutical Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.