Medication info

Diter Jumps Ultra Liquid (Sodium Hypochlorite 0.14%)

OTC medication
Ingredient · strength
Sodium Hypochlorite Solution 0.14%›Strength being verified
Manufacturer / importer
EMB Pharmaceutical Co., Ltd.
Appearance
Colorless transparent liquid
Packaging
4 liters/bottle, 500 milliliters/bottle
Approval status
Active

MFDS item code 201701117 · Approved 2017.02.28

Summary

Main use
Suppression of microorganisms through chemical sterilization and disinfection of medical devices
Who uses it
Adults
Adult dosage
Use undiluted. 1) Completely immerse the medical instrument in the disinfectant solution for approximately 1 minute (no longer than 5 minutes). Ensure adequate contact, taking care with instruments with narrow channels, such as endoscopes. 2) Rinse with a large volume of sterile purified water. Water may also be used depending on the intended use. Since disinfectant solution can readily remain inside instruments with narrow channels or complex structures, flush with sterile purified water or water under pressure, or extend the rinsing time, to rinse thoroughly.

Ingredients

Manufacturer
EMB Pharmaceutical Co., Ltd.

Efficacy & effects

Suppression of microorganisms through chemical sterilization and disinfection of medical devices

View approved original text

Chemical sterilization and disinfection of medical devices is crucial for preventing infections and maintaining a safe environment in medical settings. This method effectively removes microorganisms and pathogens that may remain on medical devices, preventing cross-infections. Chemical sterilization mainly targets medical devices that cannot withstand high temperatures, showing excellent sterilizing effects against various microorganisms depending on the type of disinfectant. Sterilization disinfection helps remove contaminants from device surfaces, protecting patients and medical staff. Through this process, the quality of patient care is improved, and a safe medical environment is established. Therefore, chemical sterilization and disinfection of medical devices play a very important role in infection prevention.

Dosage and Administration

Adult dosage

Use undiluted. 1) Completely immerse the medical instrument in the disinfectant solution for approximately 1 minute (no longer than 5 minutes). Ensure adequate contact, taking care with instruments with narrow channels, such as endoscopes. 2) Rinse with a large volume of sterile purified water. Water may also be used depending on the intended use. Since disinfectant solution can readily remain inside instruments with narrow channels or complex structures, flush with sterile purified water or water under pressure, or extend the rinsing time, to rinse thoroughly.

Precautions

This product should not be used directly on the human body. If it comes into contact with skin, immediately remove contaminated clothing and wash thoroughly with running water. If pain persists on the skin, seek treatment from a dermatologist. If it gets into the eyes, it is important to rinse immediately with running water for more than 15 minutes and seek care from an ophthalmologist. Delay or insufficient rinsing can cause eye damage. If inhaled, move to an area with fresh air and consult a specialist. If accidentally ingested, drink a large amount of water or milk but do not induce vomiting, and seek medical attention When using and storing, use a container with a lid to prevent vapor dispersal, and ensure good ventilation. It is advisable to use it in a well-ventilated area if necessary. Wear protective gear such as glasses to avoid contact with eyes and handle with caution. Reusable devices must be thoroughly cleaned of contaminants like dirt or lubricants before sterilization. When sterilizing devices, appropriate gloves, eye protection, and waterproof surgical gowns should be worn to ensure safety. Always adhere to the user manual, and use test strips to check the concentration before use. Organic materials like blood or bodily fluids on devices can reduce disinfection effectiveness, so they must be thoroughly cleaned before disinfection. For complex structured instruments like endoscopes, follow the manufacturer's cleaning methods. After cleaning, ensure that all moisture is removed from the devices before they are immersed in the disinfectant solution. Instruments made of natural rubber or raw rubber may deform and lose disinfection effectiveness with repeated use, so this should be checked. It is advisable not to use instruments that are chipped or rusted. When disinfecting, wear protective equipment to prevent infectious substances and disinfectants from entering the skin or respiratory system. Keep the product out of reach of children and store it tightly closed in the original container without transferring it to another container. Be cautious to prevent accidental ingestion or drinking, and use the solution as it is.

Side effects

  • Pain
  • eye disturbances
  • respiratory system disturbances

Not everyone experiences these, and they can vary from person to person.

Storage

This product should be stored in a tightly closed container to prevent air or moisture from entering. It is important to maintain a storage temperature between 1 degree and 30 degrees Celsius. By storing it this way, the effectiveness of the product can be preserved for a longer period.

Appearance and packaging

Appearance

Colorless transparent liquid

Package unit

4 liters/bottle, 500 milliliters/bottle

Same-ingredient medicines

Even with the same ingredient, strength, dosage form and how it is taken can differ.

Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.

Related searches

Search tags

Suggested searches

This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.