Medication info

Ophicrin Solution (O-Phthalaldehyde)

Prescription medicationSolution
Ingredient · strength
o-Phthalaldehyde›0.55g / 100mL
Manufacturer / importer
Huons Meditech Co., Ltd.
Appearance
[Plastic Container] A light blue transparent liquid in a white plastic container [Polyethylene Pack] A light blue transparent liquid in a polyethylene pack
Packaging
4 liters/bottle, 90 milliliters/pack
Approval status
Active

MFDS item code 201606718 · Approved 2016.11.23

Summary

Main use
Suppression of microorganisms on medical devices (such as endoscopes)
Who uses it
Adults
Adult dosage
1. Preparation Use undiluted. 4. Directions for use 1) Completely immerse the item to be disinfected in the solution. For instruments with lumens, take care to ensure they are in sufficient contact with the solution. 2) In general, immerse instruments for at least 5 minutes for disinfection. 3) After immersion, remove the instruments, remove any adherent material, and rinse thoroughly with a large amount of sterile water. Water may also be used depending on the intended purpose. For instruments with lumens, take care to rinse the interior.

Ingredients

Manufacturer
Huons Meditech Co., Ltd.

Efficacy & effects

Suppression of microorganisms on medical devices (such as endoscopes)

View approved original text

The sterilization and disinfection of medical instruments such as endoscopes is a process to safely manage the instruments used on patients. This procedure aims to eliminate bacteria, viruses, and other microorganisms that may remain on medical instruments, thereby reducing the risk of infection. Especially, medical instruments like endoscopes are used on multiple patients, making thorough disinfection extremely important. Proper sterilization and disinfection help prevent cross-infection and ensure patient safety. Therefore, the sterilization and disinfection of medical instruments such as endoscopes in healthcare settings are essential for infection prevention.

Dosage and Administration

Adult dosage

1. Preparation Use undiluted. 4. Directions for use 1) Completely immerse the item to be disinfected in the solution. For instruments with lumens, take care to ensure they are in sufficient contact with the solution. 2) In general, immerse instruments for at least 5 minutes for disinfection. 3) After immersion, remove the instruments, remove any adherent material, and rinse thoroughly with a large amount of sterile water. Water may also be used depending on the intended purpose. For instruments with lumens, take care to rinse the interior.

Precautions

This product can rarely cause allergic reactions, so it may be hazardous if used in poorly ventilated spaces or without wearing personal protective equipment. Avoid direct contact with eyes, skin, and clothing; contact with eyes can cause irritation, and contact with skin can result in temporary discoloration. Repeated contact with skin may lead to hypersensitivity, so if it comes into contact with the eyes, it is necessary to rinse immediately with plenty of water for at least 15 minutes and seek specialist treatment. If it touches the skin, it should also be rinsed off immediately. This product should not be used in spray form. Avoid contact with food, and if ingested, do not induce vomiting but drink plenty of water and seek medical assistance immediately. It may cause respiratory and eye irritation, so exposure to vapors should be avoided, and if vapors are inhaled, fresh air should be obtained, and medical treatment may be necessary if symptoms are severe. This product must be used according to the manufacturer's validated cleaning processes for specific medical devices, and the usage and cleaning instructions must be followed accurately. Patients with hypersensitivity or a history of bladder cancer should not use it, and it is not suitable for sterilization of heat-sensitive medical devices. This product should not be used on devices that come into contact with human sterilization areas, such as cataract surgery instruments, and it should be used in well-ventilated areas. Reusable devices must be thoroughly cleaned before disinfection, and proper gloves and protective equipment must be worn during disinfection. Users must always adhere to the instructions for use, and the manufacturer must provide validated application processes. Procedures must be followed when using automatic endoscope reprocessing equipment and the concentration of this product should be checked with a test strip before use.

Side effects

Allergic reactions, eye irritation, skin discoloration, hypersensitivity, oral irritation, throat irritation, esophageal irritation, gastric irritation, chemical burns, tingling sensation in the nose and throat, discharge, cough, chest pain, exacerbation of asthma, exacerbation of bronchitis

Not everyone experiences these, and they can vary from person to person.

Storage

This product must be stored in a sealed container to prevent exposure to air or moisture. Additionally, it is essential to store it at a cool temperature between 15 degrees and 30 degrees to maintain its effectiveness.

Appearance and packaging

Appearance

[Plastic Container] A light blue transparent liquid in a white plastic container [Polyethylene Pack] A light blue transparent liquid in a polyethylene pack

Package unit

4 liters/bottle, 90 milliliters/pack

Same-ingredient medicines

Even with the same ingredient, strength, dosage form and how it is taken can differ.

Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.

Questions about this medicine

No questions yet.

For anything that needs medical judgment, consult a doctor or pharmacist.

Related searches

Search tags

Suggested searches

This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.