Scoterin Solution (Glycine Acetic Acid 0.13%)
Peracetic Acid Solution 0.13%
OTC medication
Huons Meditec Co., Ltd.
MFDS item code 200700624 · Notified 2007.01.17 · Insurance code 670400030
Control of microorganisms by sterilizing and disinfecting medical devices (e.g., endoscopes)
For medical instruments sensitive to heat, such as endoscopes, high-temperature sterilization is difficult; therefore, appropriate low-temperature sterilization methods or chemical disinfectants are used during the sterilization and disinfection processes. This safely disinfects important medical instruments like endoscopes to prevent infections.
1. Preparation Prepare the disinfectant solution for this product as follows. Mix 4 L of Solution 1 and 90 mL of Solution 2. 2. Instructions for use A. First, completely immerse precleaned medical instruments in the prepared disinfectant solution. For instruments and equipment with fine lumens or complex structures, sufficiently wet them with the prepared disinfectant solution by pressure injection or suction. If necessary, perform a leak test before use. B. Completely immerse for at least 5 minutes. To kill spores, completely immerse for at least 10 minutes. C. After sufficient immersion, remove the instruments and rinse them under running sterile purified water for at least 15 seconds. Depending on the intended use, a larger volume of water may be used. Because disinfectant solution may remain inside instruments with fine lumens or complex structures, rinse thoroughly by pressure-injecting sterile purified water or water, or by extending the rinsing time. 3. After disinfection of the medical instruments is complete and before using them, be sure to check for residual product using a hydrogen peroxide residue test strip or similar, and confirm that the residual level is less than 0.5 ppm as hydrogen peroxide.
This product should not be used on humans. If it comes into contact with the skin, immediately remove contaminated clothing and wash thoroughly with running water. If pain persists, seek treatment from a dermatologist. If it gets into the eyes, rinse immediately with running water for more than 15 minutes and consult an ophthalmologist. Delayed or insufficient washing may cause eye damage. If vapors are inhaled, move to an area with fresh air and consult a specialist. If this product is accidentally ingested, drink plenty of water or milk and do not induce vomiting. Seek immediate medical examination. When using and storing, keep in a tightly closed container to prevent vapors from spreading, and use in a well-ventilated area; it's advisable to use it in a location with ventilation equipment if necessary. Wear protective gear such as glasses to avoid contact with the eyes and exercise caution; if it does get into the eyes, rinse immediately with plenty of water and seek medical treatment. Check to ensure the glycine acetic acid concentration is at least 0.05%, and any contaminants like blood or bodily fluids adhering to the equipment should be thoroughly washed and removed before disinfection. Complex instruments like endoscopes should be cleaned according to the manufacturer's recommended cleaning methods, and after washing, thoroughly remove moisture before submerging in the disinfectant. Check for any residues of glycine acetic acid; if residues are present, extend the rinsing time to ensure none remain. To kill spores, it should be soaked for at least 10 minutes, and it's safe not to use for more than an hour depending on the instruments or equipment. During repeated use, natural rubber or latex may be damaged, so verify the materials of the instruments used; it is advisable not to use on instruments that are cracked or rusty. When disinfecting, protective equipment such as rubber gloves, gowns, masks, and goggles must be worn to prevent infection risks and contact with the disinfectant. When storing, place it out of reach of children and ensure it is tightly closed in its original container. Prepared disinfectant should be stored away from direct sunlight at room temperature.
Not everyone experiences these, and they can vary from person to person.
This product may be sensitive to air or moisture, so it must be stored in a sealed container. The storage temperature should be maintained between 1 degree and 30 degrees Celsius. This way, the product's effectiveness can be preserved for a long time.
Component 1 - A light orange transparent liquid with an acetic acid smell contained in a white plastic bottle (orange). - A colorless transparent liquid with an acetic acid smell contained in a white plastic bottle (colorless). Component 2 - Poly.
Component 1: 4L/bottle, Component 2: 90mL/pack
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.