Acetic Acid Solution (Low Concentration Peracetic Acid Equilibrium Mixture)
Low Concentration Peracetic Acid Equilibrium Mixture
Solution · OTC medication
Saraya Korea Co., Ltd.
MFDS item code 200511464 · Approved 2005.03.19
Inhibition of microorganisms through chemical sterilization and disinfection of medical devices
Chemical methods of sterilization and disinfection will be performed during the use of medical devices. This is important for effectively removing bacteria and viruses left on medical devices to prevent infection. Various chemical disinfectants are appropriately used according to the medical environment and are selected based on the condition and type of the instruments. These sterilization and disinfection processes ensure patient safety and improve the quality of medical services. In summary, chemical sterilization and disinfection of medical devices is an essential procedure for infection prevention.
1. Preparation Prepare the disinfectant solution for this product as follows. Mix 50mL of Part 1, 50mL of Part 2, and 900mL of purified water. 2. Directions for use A. First, completely wet medical instruments that have been washed with water in the prepared disinfectant solution. For instruments and equipment with small openings or complex structures, use pressurized injection or suction to ensure they are thoroughly wetted with the prepared solution. B. Keep completely immersed for at least 5 minutes. To kill spores, keep completely immersed for at least 10 minutes. C. After thorough immersion, remove the instruments and rinse them under running sterile purified water for at least 15 seconds. Water may also be used depending on the intended use. Since disinfectant solution can easily remain inside instruments with small openings or complex structures, rinse thoroughly by injecting sterile purified water or water under pressure, or by extending the rinsing time.
This drug should not be used directly on the human body. If it comes into contact with skin, immediately remove contaminated clothing and wash thoroughly with running water; if pain persists, seek treatment from a dermatologist. If it gets into the eyes, wash immediately for more than 15 minutes with running water and seek examination by an ophthalmologist; if rinsing is delayed or insufficient, it can damage the eyes. If inhaled, move to an area with fresh air and consult a specialist. If ingested accidentally, drink a large amount of water or milk and do not induce vomiting; seek examination by a specialist. This drug has a strong irritating odor, so it should be used and stored in a well-ventilated area, and dedicated devices should be used or prepared in a well-ventilated environment to avoid vapor inhalation. Protective goggles should be worn to avoid contact with eyes, and facilities and water for washing should be prepared during preparation. Vapor can irritate the eyes and respiratory system, so goggles and masks should be worn, and inhalation or contact should be avoided. Before use, it is essential to check that the peracetic acid concentration is above 0.2%, and any residual organic matter or moisture can reduce disinfection efficacy, so instruments must be thoroughly cleaned and dried. After disinfection, check for the presence of residual peracetic acid; if any residual is found, extend rinsing time to completely remove it. To kill spores, it must be soaked for more than 10 minutes, and depending on the instrument, rust or deformation may occur, so it should not be used for more than 1 hour. Instruments made of natural rubber or living rubber may undergo deformation, so caution should be taken, and instruments that are cracked or rusty should not be used. During disinfection, protective equipment such as rubber gloves, gowns, masks, and goggles must be worn to prevent infection. The prepared disinfectant should be stored in a container with a lid, away from direct sunlight, at room temperature, and the lid should be kept closed during use. Do not prepare it for inhalation by mouth, and take care to store and handle it to prevent accidental ingestion. Since this drug is acidic, mixing it with chlorine-based preparations can produce toxic chlorine gas, so they must never be mixed. Instruments made of polyvinyl chloride or silicone resin may change color, so caution is required when using them. When disposing of it, dilute with a large amount of water or neutralize with alkali or reducing agents before disposal, and use protective equipment when disposing.
Skin pain, eye damage, irritation of the eyes and respiratory mucosa, respiratory system damage
Not everyone experiences these, and they can vary from person to person.
This drug is sensitive to light, so it should be stored in a lightproof container to avoid exposure to light. Also, it should be stored in a sealed container to avoid contact with air and ideally kept at a temperature between 1 and 25 degrees Celsius (room temperature).
A pharmaceutical product used by mixing Component 1 (active ingredient) and Component 2 (buffer stabilizer) contained in separate white polyethylene containers. (It is used as a practical solution diluted to 0.3 w/v % with purified water.) Component 1 (
750 mL, 875 mL, 1065 mL
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Low Concentration Peracetic Acid Equilibrium Mixture
Solution · OTC medication
Saraya Korea Co., Ltd.
Low Concentration Peracetic Acid Equilibrium Mixture
Solution · OTC medication
Person Co., Ltd.
Low Concentration Peracetic Acid Equilibrium Mixture
Solution · OTC medication
HP&C Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.