Unitec Technetium Sodium (99mTc) Injection Generator
Sodium Molybdate (99Mo) Solution · Sodium Pertechnetate (99mTc) Injection
Prescription medication · Combination
Samyoung Unitec Co., Ltd.
MFDS item code 200404841 · Approved 2004.04.06 · Insurance code 685100010
Diagnostic imaging of brain tumors and thyroid diseases
Technetium sodium (99mTc) injection solution is used to diagnose brain tumors or cerebrovascular disorders. It also helps accurately identify various diseases of the thyroid and salivary glands. Additionally, it is utilized in diagnosing ectopic gastric mucosa disorders. Therefore, this drug is effectively used for diagnosing diseases in various areas such as the brain, thyroid, and salivary glands.
1) Brain scintigraphy: Administer 74~740 MBq(2~20 mCi) by intravenous injection. Obtain a scintigram of the area to be examined within 10~30 minutes (if oral administration is unavoidable, 1~2 hours later). 2) Thyroid scintigraphy, measurement of thyroid uptake: Administer 74~370 MBq(2~10 mCi) by intravenous injection and obtain a scintigram of the area to be examined. When measuring thyroid uptake at the same time, compare the count rate for the administered dose with the count rate for the area to be examined. Measure thyroid uptake by intravenous injection of 7.4~74 MBq(0.2~2 mCi). 3) Salivary gland scintigraphy: Administer 185~555 MBq(5~15 mCi) by intravenous injection and obtain a scintigram of the area to be examined. If necessary, stimulate salivary secretion and obtain a scintigram after stimulation. 4) Ectopic gastric mucosa scintigraphy: Administer 185~370 MBq(5~10 mCi) by intravenous injection and obtain a scintigram of the area to be examined. Adjust the dose appropriately according to age and body weight.
Ectopic gastric mucosa scintigraphy should be adjusted according to age and weight.
This drug should not be administered to patients with obstructive pathology. Since this drug is excreted through the kidneys and gastrointestinal tract, administering it to such patients may increase radiation exposure. Rarely, hypersensitivity reactions such as red spots or rashes may occur on the skin when using this drug. Additionally, rare occurrences of vasovagal reactions, fever, allergic reactions, etc., should be noted. This drug is used only when the diagnostic benefits outweigh the risks associated with radiation exposure, and doses should be limited to the minimum possible. The radioactive materials contained in this drug may accumulate in the thyroid, choroid, salivary glands, etc., so specific medications should be taken to prevent such accumulation when performing brain scintigraphy. To minimize radiation exposure to the bladder, it is important to maintain adequate hydration before and after the examination and to urinate frequently. Medical personnel must adhere to appropriate safety protocols and handle this drug with caution to reduce radiation exposure. Since the radioactive materials in this drug have the potential to cause cancer or genetic defects, it should only be used when radiation exposure is less than the disease itself. This drug, being a radioactive pharmaceutical, can only be handled by individuals licensed as per relevant regulations, and strict rules must be followed for storage and disposal. This drug may interact with some medications, so caution should be taken regarding concomitant medications, especially during brain scintigraphy or gastrointestinal scintigraphy. Pregnant or nursing women should consult a doctor before administration, and it is generally advisable not to administer this drug if pregnancy is possible. This drug may affect fetal development, so when administering to pregnant women, careful consideration should be given to radiation exposure and pregnancy timing. During lactation, it is preferable to suspend breastfeeding for at least 3 days after administration, and express milk in the first 24 hours should be discarded. Safety for children has not been sufficiently established, so special caution is required when using in children. Elderly patients may have diminished physiological function, so their condition should be closely monitored before administration. When administering, ensure the solution is clear and transparent, and regular quality checks for the drug eluted from the generator should be conducted. When conducting brain scintigraphy, it should be noted that reading tumors in the brain base or occipital openings may be difficult.
Not everyone experiences these, and they can vary from person to person.
This drug should be stored at room temperature between 1°C and 30°C. To protect from light and moisture, it should be stored in a special container in compliance with nuclear regulatory laws. The manufacturing date, and when necessary, the manufacturing time are also indicated. Additionally, the radiation dose at the time of manufacture is recorded for safe management.
This drug is a generator that adsorbs molybdenum-99 onto alumina filled in a suitable column as ammonium molybdate or sodium molybdate and elutes technetium sodium (99mTc) injection solution.
In-house packaging unit
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Sodium Molybdate (99Mo) Solution · Sodium Pertechnetate (99mTc) Injection
Prescription medication · Combination
Samyoung Unitec Co., Ltd.
Sodium Molybdate (99Mo) Solution · Sodium Pertechnetate (99mTc) Injection
Prescription medication · Combination
Sae Han Industry Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.