Higen-HF (Ethylene Oxide)
Ethylene Oxide
OTC medication
Asia Chemical Co., Ltd.
MFDS item code 200304353 · Notified 2003.05.16
Suppression of microorganisms by sterilizing medical devices (surgical instruments, microscopes, etc.)
This medicine is used for sterilizing various medical devices, including delicate and sharp surgical instruments sensitive to high temperatures and humidity, ENT and plastic surgery instruments, microscopes, microsurgery instruments, as well as accessories for plastic and porous materials and electrical devices.
This medicine is used in connection with the following ethylene oxide gas sterilizer: Amsco Ethylen Oxide Gas Sterilizer-Aerator.
This medicine contains ethylene oxide, which may cause acute symptoms such as headache, nausea, difficulty breathing, tooth discoloration, and pulmonary edema if inhaled or in direct contact. Additionally, prolonged exposure may lead to chronic health issues such as weight loss, severe fatigue, and muscle weakness, which should be taken into consideration. Ensure that the area where this medicine is used is well-ventilated by installing ventilation systems to keep the concentration of ethylene oxide in the air low. A detector for measuring the concentration of ethylene oxide should be provided, and the concentration must be checked before and during work to ensure safety. Installing leakage alarms is advisable, and it is preferable to have water-based fire extinguishing equipment on hand. During sterilization processes, this medicine should only be used when gas sterilization methods are applied and steam or dry heat sterilization methods cannot be used; it should not be used on certain materials. Sterilization equipment must undergo regular leak tests, and the gas concentration in the work environment should be continuously monitored to ensure safety. Only trained professionals should operate sterilization equipment carefully following the user manual. After sterilization is complete, ensure thorough air circulation to eliminate residual gas, and take care to avoid gas inhalation when removing sterilized items. The storage area for sterilized items should also be well-ventilated, and exhaust should be directly discharged outdoors without affecting the surrounding environment. This medicine is a flammable gas; therefore, avoid using it near open flames. Operators should not remain unnecessarily long near sterilization devices and should ensure that gas does not come into contact with skin or is inhaled. When entering areas of high concentration, air respirators should be worn, and if the gas contacts the eyes or skin, it should be immediately washed with plenty of water and medical attention sought. Residual ethylene oxide and its by-products that may remain on medical instruments after sterilization can cause skin irritation, respiratory inflammation, and blood abnormalities, so thorough ventilation should be maintained to remove the gas. This medicine should be kept away from skin, food, utensils, children's toys, and animal feed; if it comes into contact with skin, it should be washed off with soap and water. During spraying, no one other than the person spraying should enter the work area, and after spraying, the indoor air should be adequately vented. It should not be sprayed towards humans or inhaled directly, and it should not be sprayed on ornamental fish or birds. Before use, the product should be shaken well, and after use, the cap should be securely closed for safe storage. Store it out of reach of children and avoid places with high temperatures above 40 degrees or direct sunlight.
Not everyone experiences these, and they can vary from person to person.
This medicine should be safely stored in strong pressure vessels made of aluminum alloy or steel with an internal chrome coating. Avoid direct sunlight and keep it away from sources of fire or heat. Moreover, it's important to maintain the temperature between 15 and 25 degrees at room temperature, stored in a well-ventilated area. By doing so, the medicine can be safely and effectively utilized for up to 12 months from the date of manufacture.
This medicine is a colorless and clear liquid, a non-flammable high-pressure gas that has a slight ester odor.
25kg, 50kg The container is a high-pressure gas welding container compliant with the High-Pressure Gas Safety Control Act and has passed inspection under this law.
Even with the same ingredient, strength, dosage form and how it is taken can differ.
Ethylene Oxide
OTC medication
Asia Chemical Co., Ltd.
Ethylene Oxide
OTC medication
Asia Chemical Co., Ltd.
Ethylene Oxide
OTC medication
Asia Chemical Co., Ltd.
Ethylene Oxide 100g
OTC medication
3M Korea Co., Ltd.
Ethylene Oxide
OTC medication
Daedeok Gas Co., Ltd.
Ethylene Oxide
OTC medication
Daehan Special Gas Co., Ltd.
Even with the same ingredient, the dose and directions can differ by strength and dosage form. Talk to a doctor or pharmacist before switching from a medication you are already taking.
No questions yet.
For anything that needs medical judgment, consult a doctor or pharmacist.
This drug information is based on data provided by the Korea Ministry of Food and Drug Safety.
Consult a doctor or pharmacist for accurate dosage, administration, and usage instructions.